BACnet Programmable Controllers - ECB Series
Distech Controls offers a wide range of BTL certified programmable controllersto control central plants, boilers, chillers, air handling units, roof tops, heat pumps, VAV and VVT applications, fan coil units...
All our ECB BACnet Programmable Controllers:
- operate on the BACnet MS/TP protocol (BACnet IP Communication with EC-BOS)
- deliver superior native BACnet connectivity and functionality
- are equipped with universal inputs and outputs
- support unique Open-to-Wireless solution: can be paired with an optional wireless receiver to enable communication with
- wireless battery-less devices (EnOcean technology)
- are programmable with the EC-gfx Program graphical programming tool: for more information click here
- supports Allure EC-Smart-Vue communicating LCD sensor, offering time-saving features such as air flow balancing
- and application selection; and including the innovative ECO-Vue leaf pattern which graphically indicates energy
- consumption in real time to promote energy-conscious behavior
- Supports unique Open-to-Wireless battery-less solution for additional flexibility and cost savings at installation
- deliver unmatched ease of use, with feature-rich hardware and software toolsets, to increase productivity and
- reduce installation costs
For central plants and air handling units
For VAV and VVT applications
For Terminal Equipments
For central plants and air handling units
ECB-300 Series
Applications: small and medium-sized air handling units, chillers, boilers, pumps and cooling towers...
- 10 universal inputs including 4 for fast pulse counting and metering applications
- 8 universal outputs
- Support up to 8 EC-Smart-Vue communicating sensors
- Open-to-Wireless: support of up to 28 wireless battery-less inputs
- 2 calendar, 10 schedule, 20 loop (PID), and over 300 BACnet objects
- Internal alarm functionality (feature)
- MAC Addressing: Dip switch
- 15 VDC power supply (to power 4-20mA transducers)
ECB-403 and ECB-413 Series
Applications: medium and large air handling units, chillers, boilers, pumps and cooling towers...
- 12 universal inputs including 4 for fast pulse counting and metering applications
- 8 digital (TRIAC) outputs
- 4 universal outputs
- Support up to 12 EC-Smart-Vue communicating sensors
- Open-to-Wireless: support of up to 28 wireless battery-less inputs
- 2 calendar, 10 schedule, 30 loop (PID), and over 300 BACnet objects
- Internal Alarm functionality
- MAC Addressing: Dip switch
- 15 VDC power supply (to power 4-20mA transducers)
- ECB-413: incorporates a HOA switch with potentiometer to locally override and monitor
- overridden outputs
ECB-400 and ECB-410 Series
Applications: medium and large air handling units, chillers, boilers, pumps and cooling towers...
- 12 universal inputs (including 4 for fast pulse counting and metering applications)
- 12 universal outputs
- Support up to 12 EC-Smart-Vue communicating sensors
- Open-to-Wireless: support of up to 28 wireless battery-less inputs
- 2 calendar, 10 schedule, 30 loop (PID), and over 300 BACnet objects
- Internal Alarm functionality
- MAC Addressing: Dip switch
- 15 VDC power supply (to power 4-20mA transducers)
- ECB-410: incorporates a HOA switch with potentiometer to locally override and monitor
- overridden outputs
- 16 universal inputs (including 4 for fast pulse counting and metering applications)
- 12 universal outputs
- Expandable I/O capabilities with up to 2 ECx modules for a total of 40 inputs and 36 outputs
- Open-to-Wireless: support up to 28 wireless battery-less inputs
- 2 calendar, 10 schedule, 30 loop (PID), and over 500 BACnet objects
- Internal alarm functionality
- Support up to 12 EC-Smart-Vue communicating sensors
- MAC addressing: Dip Switch
- 15 VDC power supply to power 4-20mA transducers
- ECB-610 : incorporates an HOA switch with potentiometer to locally override and monitor
- overridden outputs
ECB-600 Series
Applications: large air handling units, chillers, boilers, pumps and cooling towers.
For VAV and VVT applications
ECB-VAV and ECB-VVTS Series
Applications: from single duct to fan powered VAV with reheat and radiation heating
- 5 models to cost effectively address all VAV applications
- Universal inputs and outputs for maximum installation flexibility
- Pre-engineered configurable application selected from the EC-Smart-Vue or from EC-NetAX
- configuration pages for quick setup
- Built-in brushless DC motor actuator with intelligent damper control algorithm for extended
- actuator lifecycle and fast air flow balancing
- Open-to-Wireless: support of up to 18 wireless battery-less inputs
- Support of up to 4 EC-Smart-Vue communicating sensors
- 15 VDC power supply to power 4-20mA transducers
- Digital outputs (TRIAC) that support internal supply of 24 VAC, simplifying wiring of outputs
- such as floating actuators
- 1 calendar, 2 schedule, 8 loop (PID), and over 200 BACnet objects
- MAC Addressing: EC-Smart-Vue
For Terminal Equipments
ECB-103 Series
Applications: For two pipe fan coil, chilled ceiling, heat pump, and ventilator unit applications.
- 4 universal inputs
- 4 digital outputs (TRIAC) that supports internal supply of 24 VAC, simplifying wiring of outputs
- such as floating actuators
- 2 universal outputs
- Open-to-Wireless: support of up to 18 wireless battery-less inputs
- Support up to 4 EC-Smart-Vue communicating sensors
- 1 calendar, 2 schedule, 8 loop (PID), and over 200 BACnet objects
- 15 VDC power supply to power 4-20mA transducers
- MAC Addressing: EC-Smart-Vue
ECB-203 Series
Applications: For roof top, four pipe fan coil, chilled ceiling, heat pump, ventilator units, and small AHU systems.
- 6 universal inputs
- 5 digital outputs (TRIAC)
- 3 universal outputs
- Open-to-Wireless: support of up to 24 wireless battery-less inputs
- Support up to 4 EC-Smart-Vue communicating sensors
- 1 calendar, 2 time schedules, 8 loop (PID), and over 200 BACnet objects
- 15 VDC power supply to power 4-20mA transducers such as duct static pressure, etc.
- MAC Addressing: Dip Switch
BROCHURE
Learn more about our full range of products...
Français
Deutsch
